Enhance fire protection by reviewing fuel tank standards and repositioning vulnerable tanks
The following measures should be considered with a view to enhancing protection against fire: (i) a review of Group Standards in respect of improved crash resistance of fuel tanks; (ii) consideration of the feasibility of reducing fuel inventories and of utilising smaller fuel tanks; (iii) in respect of frontal impacts, consideration of the repositioning of fuel tanks away from the leading ends of trains from behind bogies wherever this is practicable; (iv) avoidance of placing fuel tanks in exposed and vulnerable locations; (v) examination of the use of additives to reduce the propensity of a fuel to atomise; (vi) the employment within fuel tanks of internal flexible linings or a honeycomb construction; (vii) consideration of the most appropriate material for fuel tanks; and (viii) recognition of the need for supporting theoretical and experimental work in respect of the foregoing (para 13.27).
How was this evidence gathered?
Response
Historic
Response
HistoricNo government response recorded.