Jonathan Weatherley

PFD Report Historic (No Identified Response) Ref: 2016-0206
Date of Report 2 June 2016
Coroner Caroline Beasley-Murray
Coroner Area Essex
Response Deadline est. 28 July 2016
Coroner's Concerns (AI summary)
Recall notices for the products were inadequate, failing to highlight all known problems and affected items, necessitating a comprehensive, widely distributed new recall.
View full coroner's concerns
(1) There were shortcomings in the Recall Notices which were issued in October 2015 and in March 2016.

(2) AIl the known problems with the products should be highlighted in a fresh Recall Notice (3) AII the possible products affected should be highlighted in a fresh Recall Notice Trading Standards and Upgrade Bikes should work together in order to ensure that as wide as possible an audience should be alerted to the fresh Recall Notice.
Sent To
  • Trading Standards
Response Status
Linked responses 0 of 1
56-Day Deadline 28 Jul 2016
About PFD responses

Organisations named in PFD reports must respond within 56 days explaining what actions they are taking.

Source: Courts and Tribunals Judiciary

Report Sections
Investigation and Inquest
On 24 August 2015. commenced an investigation into the death of Jonathan David Weatherley: The investigation concluded at the end of the inquest on 1 June 2016. The conclusion of the inquest was a narrative conclusion Jonathan Weatherley probably applied braking through his front brakes for an unknown reason. This caused the bonding between the carbon fibre blades and the aluminium fork crown to fail. The bonding material had not adequately bonded the two components Jonathan Weatherley died as & result of the injuries he sustained in the incident:
Circumstances of the Death
Please see above
Action Should Be Taken
In my opinion action should be taken to prevent future deaths and believe you and your organisation have the_power to take such action Cont. The
Copies Sent To
Murray Senior Coroner Essex July duty
Related Inquiry Recommendations

Public inquiry recommendations addressing similar themes

Recombinant Products Over Plasma-Derived
Infected Blood Inquiry
Medical Product Allergen Labelling

Data sourced from Courts and Tribunals Judiciary under the Open Government Licence.